Inflammaging and biostimulation: a clinical case report using high-intensity focused ultrasound and Poly-L-Lactic Acid
DOI:
https://doi.org/10.62741/ahrj.v3iSuppl.%203.260Keywords:
Inflammaging, high-intensity focused ultrasound (hifu), poly-l-lactic acid (plla), neocollagenesis, facial skin laxityAbstract
Introduction
Facial aging is a complex process resulting from the interaction between intrinsic and extrinsic factors. Inflammaging contributes to collagen degradation and impairment of the extracellular matrix, accelerating skin sagging and aging. Biostimulation, using technologies such as high-intensity focused ultrasound and injectable biostimulators, has been shown to be effective in promoting neocollagenesis and improving skin firmness, presenting itself as a promising option in orofacial harmonization.
Objective
To describe the combined effect of high-intensity focused ultrasound and injectable poly-L-lactic acid biostimulator in the treatment of facial sagging in a patient with complaints of accelerated aging. Simultaneously, the influence of inflammaging on the process is discussed.
Material and Methods
A clinical case report is presented. The patient underwent two high-intensity focused ultrasound sessions 30 days apart, followed by three poly-L-lactic acid application sessions 6 weeks apart. Before the procedure, a complete medical history and photographic study were performed. The poly-L-lactic acid protocol followed the recommendations for dilution and technique to maximize efficacy and minimize adverse effects.
Clinical Case Description
A 59-year-old female patient complained of facial sagging and accelerated aging. She had no relevant history or previous orofacial harmonization procedures. Treatment began with two high-intensity focused ultrasound sessions. After 30 days, the injectable biostimulator protocol began: poly-L-lactic acid. Dilution was performed 24 hours before the procedure to ensure product hydration, according to protocol. Applications were made at multiple facial points (malar, mandibular, and perioral regions) and cervical points.
The treatment was well tolerated, with no significant adverse effects. A gradual improvement in skin laxity and texture was observed, confirmed by clinical and photographic evaluation, with high patient satisfaction.
Discussion
This case highlights the importance of addressing inflammaging as a crucial factor in skin aging, influencing tissue response and the need for interventions that promote biostimulation. The combination of high-intensity focused ultrasound and poly-L-lactic acid allowed for synergistic action, with immediate and prolonged effects on collagen stimulation. Adequate dilution of poly-L-lactic acid, with prior hydration and addition of anesthetic, contributes to the safety and efficacy of the procedure, minimizing discomfort and complications. Future studies are needed to validate combined protocols and better understand the biological mechanisms involved
Conclusion
The combined use of high-intensity focused ultrasound and injectable poly-L-lactic acid biostimulator proved effective in improving facial flaccidity in patients with accelerated aging associated with inflammaging.
Controlling chronic inflammation through a holistic approach and promoting tissue regeneration are fundamental to orofacial harmonization. Individualized protocols and clinical follow-up are recommended to optimize results.References
NA
Downloads
Published
Issue
Section
License
Copyright (c) 2026 Athena Health & Research Journal

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Copyright of published papers is assigned to the Journal, but all content is licensed under the terms of Creative Commons Non-comercial 4.0 International License. Thus users are allowed to read, download, copy, distribute, print, search, or link to the full texts of the articles, or use them for any other lawful purpose, without asking prior permission from the publisher or the author. This is in accordance with the BOAI definition of open access.